Solutions / Membrany RO

Protection of RO membranes.
Productivity under control.

We combine water analysis, antiscalant selection, dosing and station work trends. This makes it known what reduces flow, when to react and whether to wash CIP is really needed.

  • Water Analysis and Recovery
  • Selection and control of dosing
  • Trends in membrane performance

Diagnosis before correction

Diagnosis first.

Not every change means scale. We combine water, operating parameters and station history to separate mineral sediment, impurities, biofilm and membrane damage.

Mineral residue

The salts that precipitate in the concentration limit the flow and increase membrane resistance.

Water composition and recovery

Organic and colloidal impurities

Particles and organic compounds put on the surface and shorten the cycle between washings.

SDI and pre-filtering

Biofilm

Biological development increases the pressure difference and results in increasingly less stable station work.

Microbiology and Stopping

Oxidation of the membrane

Contact with chlorine or other oxidant can permanently reduce salt retention.

Chlorine, ORP and retention

Image of station work

Four signals speak more than a single reading.

We normalize the results in terms of temperature and power conditions. Only then can you reliably compare the work of the station in time.

Permeate stream

Shows whether the station maintains the amount of water produced after taking into account temperature.

Salt retention

It allows you to evaluate the quality of separation and capture the deterioration of active layer work.

Pressure difference

Growth indicates that the flow channels are resisting more and more.

Recovery and Consumption

It combines water balance with antiscalant dose and real load of the installation.

Protection program RO

From water composition to stable membrane operation.

The treatment product is one of the elements. An effective programme combines risk projection, pre-treatment, dosing and current trend assessment.

Get to know the rules of protection RO

Power Analysis

We're testing the water composition, temperature and risk of precipitation with the planned recovery.

Reference point

Risk projection

We check where the safe range of work ends and what needs to be pre-fit.

Scope

Stable dosing

We select the treatment product, dose, injection point and flow-compatible control.

Settings and security features

Trend monitoring

We compare normalized results and react before the deviation becomes a downtime.

Decision and correction

Cleaning decision

CIP is performed when data indicates this.

Too late to wash can fix the sediment. It's too common to charge membranes and production unnecessarily. First we determine the cause of the drop in parameters.

The correct diagnosis determines the chemistry and course of washing.

Trend confirms change

The decision is based on standard flow, salt retention and pressure difference.

We recognize the type of sediment

The composition of impurities determines the order, chemistry and washing parameters.

Protect the membrane during CIP

We control pH, temperature, flow and contact time according to membrane material.

Effect on the bet

Stable station RO works predictablely.

The protection program is intended to maintain process parameters, limit unplanned interventions and give the technical team a clear basis for decision.

More stable permeate production

The work parameters are comparable over time, so deviations can be seen earlier.

Longer cycles between washings

Correct protection limits sediment and unnecessary maintenance downtimes.

Reduced energy consumption

Cleaner flow channels do not require unnecessary pressure increase.

Better investment protection

Oxidants control, dosing and CIP supports longer membrane operation.

FAQ

Questions about performance and protection of RO membranes.

Specific answers about diagnosis, anti-scalant, monitoring and the right time of CIP washing.

How can scaling be distinguished from biofouling?

We compare the difference between pressures, normal flow and salt retention with water analysis, work history and sediment from filters or CIP. The conductivity of permeate itself does not allow to reliably indicate the cause.

Can an antiscalant resolve every cause of reduced performance?

No. Antiscalant reduces the risk of precipitation of certain salts. It will not replace proper pre-filtering, biological control, oxidizer protection or proper membrane washing.

How is the antiscalant dose selected?

Based on the ion composition of water, pH, temperature, assumed recovery and concentrate conditions. Selection should also take into account the limitations of the membrane manufacturer and the actual stability of dosing.

Which parameters should be monitored daily?

Flows, pressures, pressure difference, conductivity permeate and concentrate, recovery and temperature. To assess the condition of the membranes of the value, normalize and analyse as a trend.

When should CIP cleaning be performed?

The decision is based on a change in normal flow, salt retention and pressure differential and on recommendations of the membrane manufacturer. Too late washing can fix the sediment, and too often overburdens membranes and production.

Talk about RO station

Let's see what reduces membrane performance.

Basic parameters and a brief description of the trend will suffice. Together we will determine which data should be supplemented and what next step will be the most sensible.